‘Poo and Goo’…Dialysis Effluent and the Septic Tank

This blog post was made by Dr. John Agar on June 12, 2014.
‘Poo and Goo’…Dialysis Effluent and the Septic Tank

Dori Schatell recently asked me about an interesting question posed to Home Dialysis Central by the wife of a PD patient, and it has led me on a voyage of discovery and to places with which I was quite unfamiliar.

An edited version of the question reads: “ … since my PD husband began discharging his PD fluid into our septic tank, the septic and its distribution and outflow systems have been clogging up with a clear gelatinous material…does anyone know what it is—or whether it is related to the PD effluent?”

In situations where a town drainage system exists: all city and towns, and some small villages, the effluent is simply directed into the drainage system. But, for dialysis patients (both HD and PD) who live in smaller towns, villages and rural areas where sewerage systems are not available, waste disposal can be a significant issue.

There is good information for HD:

1. Pre-dialysis reverse osmosis reject water in haemodialysis is ‘good water’ and has many uses that are way better than simply draining it to waste. These are well described at our ‘green dialysis’ website: http://www.greendialysis.org

2. However, we have known for a long time that, the post-dialyser, saline-rich HD effluent should not be directed to a septic system , as the saline concentration of the effluent damages the bacterial and fungal ecosystems that are vital to septic tank function. Indeed, this information is given in the waste-water management section of our eco-dialysis website:.

For home HD patients, the message is clear: don’t discharge post-dialyser effluent to the septic!

But…the PD literature has no available information to guide disposal practices for PD effluent in unsewered situations. I went searching.

Hey, presto! While the dialysis literature is void on the subject, the wine-making literature is not! There is a wealth of information warning small wineries to avoid discharging the sugar-rich effluents generated by the crushing process into an anaerobic septic system especially a small one.

It seems that the typical total organic glucose content in the effluent from a winery varies from 1,000 to 5,000 mg/L , the latter being reached during the crushing season. This corresponds to the period when wine industry septics are at maximum risk of clog and fail. This sugar content is expressed as the biological oxygen demand (BOD) of the effluent, with a BOD of <5,000 being a regulatory maximum. A septic tank expert from the wine-growing region of Margaret River in Western Australia has informed me (personal communication: Tony, ElutiateSystems) that a BOD >5,000 risks the formation of a gelatinous co-polymer over the surface of the septic system and in its’ feed and outflow pipes, a gelatinous ‘goo’ rather like solid egg white, that clogs and damages the septic system, causing failure.

PD fluid effluent is far more “sugary” than that!

1.5% PD solution contains 1.5gm/100ml of glucose = 15gm/L (or 15,000 mg/L), effectively equivalent to a BOD three times the upper regulatory BOD limit for discharging wine industry effluent to a septic system. 4.25% PD fluid contains 42,500gm/L, a factor of nearly ten times the recommended upper BOD limit for winery effluent discharge into an anaerobic septic tank system. (For data on PD fluid sugar content, see Table 1 of the Baxter PDF https://www.baxter.com/downloads/patients_and_caregivers/products/dianeal_ultrapd2.pdf ).

Combine this huge glucose-generated BOD, plus a small surface area system, plus a low total daily water flow (and thus a limited capacity for a dilutional effect), plus the presence in the PD effluent of some PD patients of a significant albumin concentration, plus the high sodium content of PD fluid (NB: note the issue with HD effluent), plus who knows what other factors—and it seems likely that this would set up a recipe for septic tank system failure.

The Department of Environment and Agriculture, Curtin University, Perth, Western Australia, has conducted research for the Margaret River wine region on this issue, published a series of fact sheets for the Wine Industry, and generated a series of effluent recommendations around septic system size relative to water flows, and “substance content” limits for the effluent, with one of those substances being sugar! See: WineWatch: Fact Sheet 4. Subsurface disposal of winery wastewater for small wineries. http://environmentagriculture.curtin.edu.au/local/docs/winewatch/Winewatch_Fact_Sheet_4.pdf

So, the short answer for PD patients may also be: Do not discharge PD effluent into a small anaerobic septic tank. It risks the rapid generation of a clogging co-polymer that blocks up the septic.

All that said, there are patient discussion sites where anecdotal evidence suggests that while some patients have problems with their septic tanks (as above), others have not. (http://ihatedialysis.com/forum/index.php?topic=26883.0,)Why there seems to be this disparity is uncertain. That it exists, however, seems sure.

But, as the Fresenius Report ‘ESRD patients in 2012 – A Global Perspectives’ states, there are ~252,000 PD patients exist world-wide and, as it is inevitable that many of these patients will live in regions where sewerage systems are scarce, this seems a relevant topic to better understand.

We have, as dialysis professionals, been abysmally slow to recognise and consider the environmental impact of the things we do. To begin to redress this short-coming, the effect of HD and PD effluents on septic tank function would seem a more than useful dialysis-related research project to conduct in cooperation with the septic tank industry. Until then, I can only guess that the high sugar (dextrose), sodium and albumin concentrations of PD effluent, and the high sodium content of HD effluent either feed the wrong organism populations and/or damage the “good” bacterial balance that is essential for normal septic tank function.

For those interested, there is a good PDF discussion of septic tank function at:

www.septic.umn.edu/prod/groups/cfans/@pub/.../cfans_asset_131292.pdf

So, what should be done with PD drainage? In home HD in Australia, we recommend HD effluent drainage into an open or, preferably, a rocked pit—remembering that in Australia we use single pass systems (Fresenius or Gambro/Baxter) for home HD, systems that generate much larger volumes of post-dialyser fluid effluent. Perhaps this would be a good suggestion for PD as well.

Comments

  • Mark Nelson

    Aug 01, 2019 12:28 PM

    I've got the drain from my PD cycler running to my bathroom sink and have noticed that sink clogs easily and often. I plunged it out and got chunks of a clear whitish substance that looked like jellyfish. I am certain it is from the high dextrose content in the effluent. I am going to try moving the drain to the toilet instead.
    Reply to a Comment
    *All fields are required.
    Your email will not be displayed publicly
    • Robin

      Jun 22, 2021 7:08 PM

      I had a line going to the toilet every night to drain my fluid. The toilet was flushed in the morning. If the toilet was not washed daily a clear gelatinous film would build up on the sides of the bowl. Residue buildup from the fluid sitting nightly.
      Reply to a Comment
      *All fields are required.
      Your email will not be displayed publicly
    • John Agar

      Aug 06, 2019 5:30 AM

      Your description of a 'jelly fish' appearance makes me think this whitish material is probably mainly fibrin - a common and normal component of PD effluent. A recent question at the Home Dialysis central Message Boards raised the issue of PD fibrin exudation in the context of heparin additives to PD fluid ... see: https://forums.homedialysis.org/t/use-of-heparin-on-pd/7130/5 ... and I think this falls into the same category. I wouldn't be too anxious about it if there are no clinical PD fluid drainage issues, but I can understand how it could be an issue for your plumbing.!
      Reply to a Comment
      *All fields are required.
      Your email will not be displayed publicly
  • Lally mackenzie

    Sep 24, 2018 10:22 AM

    As we have learned we must dig arock pit for emptying dialysis fluid so as to not ruin septic system, we wonder how to accomplish this taking into acount minus 30 degreec winters. Thanks if you have solved this!
    Reply to a Comment
    *All fields are required.
    Your email will not be displayed publicly
    • John Agar

      Sep 24, 2018 11:48 PM

      Sorry, Lally, but in Australia, minus temperatures just dont come round.

      I think you will need local know-how to solve this one.
      Reply to a Comment
      *All fields are required.
      Your email will not be displayed publicly
      • Joseph D Mays

        Jul 31, 2022 9:41 PM

        What size would a rock pit need to be for a single home with a single patient on HD?
        Reply to a Comment
        *All fields are required.
        Your email will not be displayed publicly
  • Dorothy May Smith

    Jul 08, 2014 1:53 PM

    i live in uk with water going straight to sewers ?
    Reply to a Comment
    *All fields are required.
    Your email will not be displayed publicly
Leave a New Comment